BT UC-351GP/E-UK Manual de instalación Pagina 16

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 40
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 15
BT Redcare Secure Issue 16 June 2010
Installation Manual Page 16 of 40 All rights reserved
Configuring Panel Format
By default the unit is configured for pin-only mode. This mode disables the dial capture port to
reduce power consumption. Use the following command to enable the dial capture port and set it
to receive the relevant panel format where dial capture is required. Note Pins can still be reported
in any of these other modes.
To change the panel format, use the * 15 * option:
* 15 * 1 # ContactID
* 15 * 10 # High Speed (fast format)
* 15 * 20 # SIA
* 15 * 30 # Pin Only mode - default
The Redcare Secure unit supports several other less common formats listed below:
* 15 * 2 # ContactID with Double Knock
* 15 * 3 # 4 + 1 express (DTMF mode only)
* 15 * 5 # 4 + 2 express (DTMF mode only)
* 15 * 11 # High Speed with Double Knock
* 15 * 21 # SIA with V21 tones
If no more parameters are to be configured, remove the header from J903 and disconnect the
DTMF phone.
Configuring General Purpose Outputs
By default, the Redcare Secure unit‟s General Purpose Outputs (GPOP‟s) operate as follows:
Output
Default Function
Default Polarity
GPOP1
Local path fail output
High to indicate dual path
failure.
GPOP2
Remotely (ARC) Controlled
0 from ARC sets output High, 1
from ARC sets output Low
GPOP3
RPS function (in conjunction with input pin 4)
Alarm sent sets output High,
Alarm ack‟d sets output Low
Figure 11 - General Purpose Output Pin operations
The following commands can be used to configure the behaviour of the GP Outputs:
GPOP1
* 91 * 20 BSIA Form 175 Mode default mode
* 91 * 30 Standard Path Fail Mode Active Low (Failure of any communications path causes a
Low on GPOP1)