BT Redcare Secure Issue 16 June 2010
Installation Manual Page 29 of 40 All rights reserved
Connecting alarm pin inputs
For alarm panels that provide „Positive applied‟ or „Positive removed‟ communicator outputs, the
unit‟s input pins can be wired directly to the Alarm panel.
Figure 20 - Alarm panel with Positive Applied or Removed communicator outputs
For alarm panels that have open collector communicator outputs (sometimes referred to as
„Negative Applied‟ outputs) an additional 10K pull-up resistor will be required to be connected for
each input pin.
Figure 21 - Alarm panel with Open collector (Negative applied) communicator outputs with
an additional 10K pull up resistor for each pin
Note: Ensure the 0V of the alarm panel is Commoned to the 0V of the Redcare Secure unit when
separate Power Supply Units are used.