BT UC-351GP/E-UK Manual de instalación Pagina 22

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 40
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 21
BT Redcare Secure Issue 16 June 2010
Installation Manual Page 22 of 40 All rights reserved
7 Network Registration and Commissioning
Ensure both Config and learn headers are removed.
If Config Header (J903) is shorted, the unit will not attempt to register on the BT Redcare
Enterprise Service Platform (ESP). The header short should be removed once configuration is
complete.
Network Registration
On startup, the unit will immediately attempt to register on the BT Redcare ESP with all available
interfaces:
- GPRS
- PSTN or Ethernet
During registration and also in normal operation, the meaning of the LED indications is as follows:
State
Wireline (LED 2)
Wireless (LED 3)
Off
Either:
The unit is in the process of starting up
or:
The wireline path is not available.
i.e. Ethernet port cannot obtain an IP
address or PSTN path was unable to
complete the last dial up attempt)
Either:
The unit is attempting to obtain an IP
address
or:
The wireless interface is not available
Slow Flash
1s Off 1s On
The Unit is attempting to set up an IP
path to the ESP. (i.e. Ethernet port has
obtained an IP address and is
attempting to reach the ESP. Or PSTN
is attempting to establish a dial up call)
The unit has an IP address over its
wireless (i.e. GPRS) interface and is
attempting to contact the ESP
Fast Flash
250ms Off
250ms On
PSTN path has a call in progress and is
communicating with the ESP
N/A
Blink
50ms On
950ms Off
PSTN path has detected PSTN voltage
fail < 1.5V on PSTN
N/A
On
The unit is connected to the BT Redcare
ESP via IP, or the last PSTN dial up call
was successful.
The unit is connected to the BT
Redcare ESP via GPRS
Figure 14 - Wireline and Wireless LED indications
Vista de pagina 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 39 40

Comentarios a estos manuales

Sin comentarios