BT Redcare Secure Issue 16 June 2010
Installation Manual Page 26 of 40 All rights reserved
Apply an alarm / restore condition to all used input pins.
These events will be signalled immediately over GPRS path if available.
Pin 3 intruder alarm event
Pin 7 confirmed intruder alarm event
Pin 2 panic alarm restore
Pin 3 intruder alarm restore
Pin 7 confirmed intruder alarm restore
Pin 12 Tamper alarm restore
Figure 18 - Typical ARC alarm log for Redcare Secure unit test pin alarms during
commissioning
Check with the ARC that these alarms have been received over the relevant paths.
Remote trigger of dual path test
The ARC can send the telemetry command ID=01, Data=00 to cause the Redcare Secure unit to
send a BSIA test message on all available paths. Within 70 seconds a pin 988 Event / Restore
will be received via each path.