BT Redcare Secure Issue 16 June 2010
Installation Manual Page 33 of 40 All rights reserved
Appendix B BT Redcare Secure unit Generated Events
BT Redcare Secure generates events for system alarms. The values listed in Figure 22 are the
codes that are signalled by the unit in ContactID, Fast Format and SIA modes.
Alarms sent over wireline can be differentiated from those sent over wireless by the Receiver
Number field in the Automation Protocol.
Description
Pin
CID
(zone)
SIA
(zone)
FF
(zone)
Time to Active
Low DC Input Level
985
302 (999)
YT/YR
6 (2)
E Immediate; R Immediate
PSTN voltage fail
955
356 (999)
LT/LR
6(5)
E 120s; R 30s
Bad Packet Count
Threshold Exceeded
959
352 (999)
ET/ER (999)
6 (3)
E Exceed Count;
Bad Checksum
958
311 (999)
ET/ER (993)
6 (3)
E Exceed Count;
Missing Heartbeat
982
312 (999)
ET/ER (991)
6 (3)
E 10 days; R Immediate
Off Hook Timeout
957
313 (999)
ET/ER (989)
6 (3)
E 10 Min; R Immediate
Dial Fail
983
314 (999)
ET/ER (987)
6 (3)
E 20 Sec; R Immediate
Runaway Panel
956
316 (999)
ET/ER (983)
6 (3)
E 10 Min; R Immediate
Panel Disconnected
992
317 (999)
ET/ER (981)
5 (1)
E 2 Min; R Immediate
GPIP1-16
1-16
323
(901-916)
UA/UR
(901-916)
7 (1)
E Immediate; R Immediate
Software Mismatch
979
304 (999)
ET/ER (979)
6 (3)
E Immediate
Panel Type
Mismatch
989
311 (998)
ET/ER (977)
6 (3)
E Immediate
BSIA 175 Test
988
354 (997)
TX/TE
6 (3)
E Immediate; R Immediate
Unit Restarted
984
305 (995)
AT/AR (995)
5 (6)
E Immediate; R Immediate
Level 3 Access
978
627 (999)
RB (999)
5 (3)
E Immediate
Panel Download
993
LB/LX (999)
E Bypass on; R Bypass off
Figure 22 - BT Redcare Secure Reported Events